Start the observationsΒΆ

$ : commands to insert in a shell

> : commands to insert in the operatorInput panel

logo: check the execution on the monitor


  1. Insert your project number

    > project=[projectID] logo Fig.21

  2. Initial setup

    > antennaReset

    > setupCCB logo Fig.18

  3. Select the active surface shape (Shaped configuration for C-band observations)

    > asSetup=S logo Fig.4

  4. Insert the Local Oscillator value in MHz

    > setLO=[freq] logo Fig.18

  5. Follow the link below to perform the pointing and focus optimization (if not already included in your schedule) :

  6. Select and configure the SARDARA backend

    > chooseBackend=Sardara logo Fig.21

    $ genericBackendTui BACKENDS/Sardara

    > initialize=SC00S for full Stokes observations or > initialize=SC00 for total intensity observations

    Important note: both SARDARA configurations SC00S and SC00 are set to work with a default bandwidth of 1500 MHz and 1024 channels. Only in the event that you wanted to observe with different bandwidth and/or channel values you have to set the parameters of the backend (see the following item).

  7. Set the different parameters of the backend :

    > setSection=[sect],*,[bw],*,*,[sampleRate],[bin] logo Fig.13

    with :

    • [sect]: 0 in full Stokes observations ;
    • [bw] the bandwidth in MHz (420 or 1500 MHz) ;
    • [sampleRate] in MHz (840 for 420 MHz of bw or 3000 for 1500 MHz di bw) ;
    • [bin] the frequency channels (1024 or 16384).
  8. Choose the integration time in ms (e.g. n=10 corresponds to 100 spectra/sec)

    > integration=[n]

  9. Put the antenna at 45 deg of elevation before checking that the signal is in the linear range of the backend:

    > goTo=*,45d logo Fig.15

  10. Check that the getTpi command is working correctly before proceeding:

    > getTpi

    If getTpi=0,0 then there is a problem, you need to ask for help. If getTpi=(a few millions) then proceed.

  11. Attenuate the signal based on the rms range [20;22] and check the value on the interface.

    > getRms

    > setAttenuation=[sect],[att] with [att] the attenuation from 0 to 15 dB. logo Fig.13

  12. Check the tsys (typical values 30-35 K)

    > tsys logo Fig.13

  13. Report the ground temperature, relative humidity, atmospheric pressure, and wind speed :

    > wx

  14. Begin the schedule by indicating the start scan [N] or subscan [N_n] in the SCD file :

    > startSchedule=[schedulename].scd,[N] logo Fig.21